W/TH: How Bitcoin Miner Efficiency Is Measured

W/TH: How Bitcoin Miner Efficiency Is Measured

W/TH (watts per terahash), also written J/TH (joules per terahash), is a unit of energy efficiency for Bitcoin mining machines that shows how many watts of electricity a machine draws for each terahash per second (TH/s) of hashrate it produces. A lower W/TH is better, because the machine spends less electricity on the same amount of work.

Why Are W/TH and J/TH the Same Number?

W/TH is a machine’s power draw divided by its hashrate. Hashrate is the number of hash calculations a machine performs each second. Each hash is one attempt at finding a valid block. A terahash is 1 trillion hashes, so the full name of the unit would be watts per terahash per second.

The “per second” disappears from the name because a watt already contains it. One watt is one joule of energy per second, so dividing joules per second by terahashes per second cancels the seconds and leaves joules per terahash (J/TH). A machine rated at 13.5 J/TH spends 13.5 joules of energy on every trillion hashes it computes.

W/TH and J/TH are therefore the same number under two labels. Bitmain’s spec sheets for machines such as the Antminer S19 XP and the Antminer S21 XP Hyd list efficiency in J/TH, while GoMining’s documentation lists it in W/TH.

A lower W/TH means a more efficient machine. A falling W/TH is often described as higher efficiency, which can confuse readers who expect a better number to be a bigger one. If TH/s is a machine’s horsepower, W/TH is its fuel consumption, so a machine at 13.5 W/TH uses less energy for the same work than one at 21.5 W/TH.

How Do You Calculate W/TH from a Spec Sheet?

A spec sheet prints the figures the calculation needs: the hashrate in TH/s and the power draw in watts (W). Bitmain labels the power figure “power on wall.” Dividing the watts by the TH/s gives the machine’s W/TH.

Bitmain’s Antminer S21 XP works as an example. As of October 2026, Bitmain’s specifications for the S21 XP list a typical hashrate of 270 TH/s and a power draw of 3,645 W, measured with 25 °C inlet air. Inlet air is the cooling air that enters the machine.

Dividing 3,645 W by 270 TH/s gives 13.5 W/TH for the Antminer S21 XP. That result matches the 13.5 J/TH efficiency that Bitmain lists for the same machine.

The watt figure on its own is the power consumption of a Bitcoin mining machine. W/TH expresses that power consumption per unit of work, which puts a small machine and a large one on the same scale.

Some lists give the hashrate of large Bitcoin machines in petahashes per second (PH/s) rather than TH/s. One PH/s equals 1,000 TH/s, so the figure has to be converted to TH/s before the watts are divided by it.

How Does W/TH Turn into an Electricity Bill?

A W/TH figure converts directly into energy per day. You multiply W/TH by 24 hours to get watt-hours for each TH/s per day, then divide by 1,000 to get kilowatt-hours (kWh), the unit an electricity bill charges for. At 13.5 W/TH, each TH/s of hashrate uses 324 watt-hours, or 0.324 kWh, every day.

Multiplying a daily energy figure by a power price turns it into a cost. The price used here, $0.10 per kWh, is an example only and not a GoMining rate. The example sits near the average US industrial electricity price of $0.0964 per kWh (9.64 cents) that the US Energy Information Administration reported for August 2026. At the example price of $0.10 per kWh, the 0.324 kWh that each TH/s uses at 13.5 W/TH costs about $0.032 a day.

As listed by Bitmain in October 2026, the whole Antminer S21 XP draws 3,645 W, so running around the clock it uses about 87.5 kWh a day. At the example price of $0.10 per kWh, which is not a GoMining rate, that energy costs about $8.75 a day.

The older Antminer S19 XP, which Bitmain rates at 21.5 W/TH as of October 2026, shows what a higher W/TH does to the same arithmetic. The S19 XP needs 0.516 kWh per TH/s per day, against 0.324 kWh for the S21 XP. The S19 XP therefore uses about 59% more electricity than the S21 XP for the same work.

ModelW/THkWh per TH/s per dayCost per TH/s per day (USD) at an example $0.10 per kWh
Antminer S19 XP21.50.5160.0516
Antminer S21 XP13.50.3240.0324
Antminer S21 XP Hyd12.00.2880.0288

Calculated from Bitmain’s spec-sheet efficiency figures, as of October 2026, at an example price of $0.10 per kWh, which is not a GoMining rate.

For each unit of work, the electricity cost of Bitcoin mining comes from two numbers multiplied together. W/TH sets how much energy each unit of work takes, and the power price sets what each kWh of that energy costs.

How Much More Efficient Have Bitcoin Miners Become?

Bitcoin miner efficiency has improved as newer ASIC (application-specific integrated circuit) machines have replaced older ones. An ASIC is a chip designed for one particular use, and a Bitcoin ASIC is built for SHA-256, the hash function that Bitcoin mining runs. Three of Bitmain’s machines show how far the figure has fallen.

ModelTest conditionHashrate (TH/s)Power (W)Efficiency (J/TH)
Antminer S19 XP25 °C1413,031.521.5
Antminer S21 XP25 °C inlet air2703,64513.5
Antminer S21 XP Hyd35 °C inlet water4735,67612.0

Values from Bitmain’s spec pages, as of October 2026.

In Bitmain’s spec pages as of October 2026, the energy spent on one trillion hashes falls from 21.5 joules on the Antminer S19 XP to 12.0 joules on the Antminer S21 XP Hyd. The Antminer S21 XP Hyd is hydro-cooled, which means liquid in a water loop carries heat away from the machine. Bitmain measures the S21 XP Hyd with 35 °C inlet water instead of the 25 °C reference it uses for the Antminer S19 XP and S21 XP, so the hydro model’s figures come from a different test condition.

A digital bitcoin miner from GoMining is defined by its mining power, measured in TH, and its energy efficiency, measured in W/TH. GoMining’s documentation describes the mining power as the miner’s average hashrate in TH/s, and the energy efficiency as how many watts the miner uses for each TH.

GoMining charges a daily maintenance fee that covers electricity and equipment service and deducts it from the miner’s BTC rewards. The lower a digital miner’s W/TH, the lower the electricity part of that fee. The energy efficiency of a GoMining digital miner can be upgraded in the GoMining app, and each upgrade has a price.

What W/TH Does Not Tell You

W/TH is not a machine’s total power draw. As listed by Bitmain in October 2026, the Antminer S21 XP draws 3,645 W, more than the 3,031.5 W of the older Antminer S19 XP, yet the S21 XP uses far less energy for each terahash. Total watts set the size of a machine’s whole electricity bill, while W/TH sets the energy cost of each unit of work.

W/TH does not decide a machine’s rewards. A bitcoin miner’s rewards depend on network difficulty, on the block reward, and on how much hashrate the machine contributes. The block reward is the block subsidy of newly created BTC plus the fees of the transactions in that block.

Network difficulty is a number that expresses how hard it is to find a valid block. Bitcoin recalculates network difficulty every 2,016 blocks to keep blocks arriving about every 10 minutes, and difficulty rises when blocks have been arriving faster than that. When network difficulty rises, each hash a machine computes has a smaller chance of producing a valid block, so a machine with the same hashrate and the same W/TH can be expected to earn less BTC.

The BTC price sets what a machine’s BTC rewards are worth in dollars, and the power price sets what its electricity costs. A low W/TH lowers one cost, but it does not by itself decide whether the result after costs is positive.

Spec-sheet figures are values measured under a test condition. As of October 2026, Bitmain lists the Antminer S21 XP’s figures as typical values, measures its power and efficiency with 25 °C inlet air, and states a tolerance of plus or minus 3% on hashrate and plus or minus 5% on power and efficiency. A given S21 XP can therefore differ from its printed 13.5 W/TH by up to about 5% under that test condition. Bitmain’s spec pages do not say how other operating conditions change the figure.

W/TH tells you what each terahash costs in energy, not what it earns. Once you know that difference, you can read a spec sheet in J/TH or W/TH, turn the figure into kWh per day, and see which questions efficiency cannot answer alone.

November 16, 2026